The XAS 400-200 PACE JD is a single-stage, oil-injected, rotary screw type air compressor, powered by a liquid-cooled, four-cylinder turbocharged diesel engine.
The unit consists of an air end, diesel engine with exhaust treatment, cooling circuit, air/oil separation and control systems - all enclosed within a sound dampened HardHat™ enclosure.
A range of undercarriage formats, factory and locally installed options are available. Special attention has been given to the overall product quality, user friendliness, ease of serviceability, and economical operation to ensure best in class cost of ownership.
Optimize your fleet investment, improve utilization and get a higher return on investment. If you are using multiple machines to cover flow demands between 365-410 cfm and pressure ranges from 150-200 psi, then now is the time to stop.
The intuitive PACE system (Pressure Adjusted thru Cognitive Electronics) gives you the most options from a single compressor. The Xc2003 controller is the secret behind our “versatility range”. These compressors can work on various pressure settings, thanks to the built-in PACE technology. One compressor can deliver 150 psi for sandblasting or 200 psi for cable blowing.
The Xc2003 also holds more parameters that help you get the most out of your compressor. Full diagnostics, insight into your compressor’s utilization and information about planned maintenance. It’s all there.
Actual free air delivery (FAD) | Cfm | 365 - 410 |
Normal effective working pressure | Psi | 150 - 200 |
Maximum unloading pressure | Psi | NA |
Minimum working pressure | Psi | 72 |
Max. sound pressure level @ 23’ (7m) at normal working speed & pressure2 | dB(a) | 76 |
Compression Stages | 1 |
|
Air Receiver Capacity | US Gal (L) | 11 (41.6) |
Compressor oil capacity | US Gal (L) | 6.3 (23.8) |
Approximate air outlet temperature | °F (°C) | 200 (93) |
Air Compressor outlets | 2 x ¾” & 1 x 1 ½“ | |
Max. ambient temperature (at sea level)3 | °F (°C) | 122 (50) |
Maximum altitude | Ft (m) | TBD |
Minimum starting temperature (without cold weather options) | °F (°C) | NA |
Minimum starting temperature (with cold weather options) | °F (°C) | -13 (-25) |
Engine | John Deere | 4045EWL |
Emissions Regulation | US EPA Tier | T4F |
Output at rated speed (2400 rpm) | HP | 148 |
Number of cylinders | 4 | |
Aspiration | Turbocharged | |
Displacement | cu in (L) | 269 (4.5) |
Engine speed (Unloaded) | Rpm | 2000 |
Engine speed (Maximum loaded) | Rpm | 2200 |
Engine oil capacity | US Gal (L) | 5.4 (20.4) |
Engine oil required | Low Ash Oil per API CJ-4, ACEA C9 | |
Engine coolant capacity | US Gal (L) | 6.25 (23.6) |
Fuel tank capacity | US Gal (L) | 52 (197) |
Fuel consumption at 0% load | Gal/Hr (L/Hr) | 3 -4 (11.4 - 15.1) |
Fuel consumption at 100% load | Gal/Hr (L/Hr) | 7 (26.5) |
DEF tank capacity | US Gal (L) | 5 (18.9) |
DEF consumption at 100% load | Gal/Hr (L/Hr) | 0.33 (1,25) |
Battery Capacity (Cold Cranking Amps4) | A | 1150 |
Pneumatic Directional boring refers to smaller-diameter bores over shorter distances while horizontal directional drilling, or HDD, indicates larger diameters and longer distances.
PDB and HDD are trenchless technologies that use surface-launched equipment to drill underground horizontally and install pipes, conduits, and cables. These processes can be air-driven and are used in numerous industries, such as utilities and telecommunications, at sites in dense, urban areas and/or where traditional vertical excavations are too dangerous (e.g., under bodies of water).
Sandblasters are used to clean difficult substances like rust or paint from solid surfaces like metal. In order to choose the correct compressor unit for sandblasting it is important to understand that the compressor doesn’t simply provide a single burst of air. It must sustain the pressure needed for the specific equipment and operation. The compressor needs to have the right air volume. Too little and it won’t be able to keep up with your job, too much and you will have paid for capcity you don't need.
The units were tested both in lab and field conditions to ensure optimal performance. It’s designed to withstand the toughest working conditions. We have a mobile compressor for any indoor or outdoor application. On top of peace of mind, you'll also gain low noise levels, small footprint, fuel efficiency or zero diesel emissions, high resale value, easy to use and intuitive controllers... and much more.
The 400 cfm range extends the compressor oil service interval to 1000 hours or once every two years. Reduced service intervention and longer life of consumables reduces total cost of operation and increases availability.