Cost Saving Opportunities for Compressors
28 六月, 2022
In many compressed air installations there are often significant and unutilized cost-saving possibilities. Learn more on how to save on compressor running costs here.
Many installations that produce compressed air offer significant and frequently unutilized energy saving possibilities in the form of waste energy recovery. In large industries, energy costs can amount to 80% of the total cost of compressed air production. However, a lot of this energy can be recovered, which in turn will save you a lot of money.
A compressor central plant in a large industry that consumes 500 kW over 8,000 operating hours per year represents a yearly energy consumption of 4 million kWh. The possibilities for recovering substantial amounts of waste heat via hot air or hot water are real. As much as 94% of the energy supplied to the compressor can be recovered, for example, as 90°C hot water from oil-free screw compressors. This fact illustrates that saving measures quickly provide substantial return. The return on investment for energy recovery is usually as short as 1–3 years. In addition, energy recovered by means of a closed cooling system enhances compressor operating conditions, reliability and service life due to an equalized temperature level and high cooling water quality, to name but a few advantages. Nordic countries are somewhat of a forerunner in this arena and energy recovery has been standard practice for quite some time now for compressor installations. Most medium to large compressors from the major suppliers are now adapted for fitting with standard equipment for waste heat recovery.
The laws of physics dictate that nearly all energy supplied to a compressor installation is converted into heat. The more energy that can be recovered and utilized in other processes, the higher the system's overall efficiency.
In many cases the degree of heat recovery can exceed 90% if the energy gained by cooling the compressor installation can be utilized efficiently. The function of the cooling system, the distance to the point of consumption, and the degree and continuity of the heat requirement are all decisive factors. With large thermal flows, selling the recovered heat energy is a possibility that should not be ignored. The electrical energy supplier could be a potential customer, and investment, sub-order and delivery could readily be negotiated. An opportunity for savings also exists by coordinating energy recovery from several processes.
Energy recovery from compressed air installations does not always result in heat when it is required and oftentimes, not in sufficient quantities. The quantity of recovered energy will vary over time if the compressor has a variable load. In order for recovery to be feasible, a corresponding relatively stable heat energy demand is needed. Recovered waste heat energy is best utilized to supplement energy supplied to the system. That way the available energy is always utilized when the compressor is operating. Options for air-cooled compressors, which produce a high hot air flow rate at a relatively low temperature, are direct building heating or heat exchanging to a preheating battery. The heated cooling air is then distributed using a fan. When buildings do not require additional heat, the hot air is evacuated into the atmosphere, either automatically by thermostat control or manually by controlling the air damper. A limiting factor is the distance between the compressors and the building that needs to be heated. This distance should be limited (preferably the distance between adjoining buildings). Furthermore, the possibility of recovery may be limited to the colder periods of the year. Airborne energy recovery is more common for small- and medium-sized compressors. Recovery of waste heat from compressor air cooling systems results in only small losses from the distribution and requires little investment.
The cooling water from a water-cooled compressor with a temperature up to 90° can supplement a hot water heating system. If the hot water is used instead for washing, cleaning or showering, a normal base load hot water boiler is still required. The energy recovered from the compressed air system forms a supplementary heat source that reduces the load on the boiler, saves heating fuel and could potentially result in the use of a smaller boiler. Prerequisites for energy recovery from compressed air compressors differ in part depending on the type of compressor. Standard oil-free compressors are easy to modify for energy recovery. This type of compressor is ideal for integration in a hot water heating system since it provides the water temperature (90°C) required for efficient energy recovery. On oil-lubricated compressors, the oil, which takes part in the compression process, is a factor that limits the possibilities for high cooling water temperatures. In centrifugal compressors, the temperature levels are generally lower because of the lower pressure ratio per compression stage, thereby limiting the degree of recovery. Waterborne waste energy recovery is best suited to compressors with electric motor power over 10 kW. Waterborne recovery of waste energy requires a more complex installation than airborne waste energy recovery. The basic equipment consists of fluid pumps, heat exchangers and regulation valves. Heat can also be distributed to remote buildings using relatively small pipe diameters (40-80 mm) without significant heat losses using waterborne energy recovery. The high initial water temperature means that waste energy can be used to increase the temperature of the return water from a hot water boiler. Therefore, the normal heating source can be periodically switched off and be replaced by the compressor's waste heat recovery system. Waste heat from compressors in the process industry can also be used to increase the temperature of the process. It is also possible to use air-cooled oil-lubricated screw compressors to apply water-borne waste energy recovery. This requires a heat exchanger in the oil circuit, and the system will provide water at lower temperatures (50° - 60°) than with oil-free compressors.
壓縮空氣結合電力、水和氣體,讓我們的世界運轉起來。我們不一定常看到壓縮空氣,但它就在我們身邊。由於壓縮空氣有許多不同的用途 (和需求),因此壓縮機現在才有各種不同的類型和尺寸可供選擇。在本指南中,我們概述壓縮機的功能、您需要壓縮機的原因,以及您有哪些選擇。
您是否需要任何額外協助?按一下以下按鈕,我們的專家很快就會與您聯絡。
28 六月, 2022
In many compressed air installations there are often significant and unutilized cost-saving possibilities. Learn more on how to save on compressor running costs here.
25 四月, 2022
A number of decisions must be made when dimensioning compressed air installation for it to suit different needs, provide maximum operating economy and be prepared for future expansion. Learn more.
31 五月, 2022
Installing a compressor system is easier than it used to be. There are still a few things to keep in mind though, most importantly where to place the compressor and how to organise the room around the compressor. Learn more here.