Visit The Compressed Air Blog!

Are you looking to learn more about the compressed air industry? Do you have pressing questions about compressed air and gas systems?
The Compressed Air Blog illustration

Beer, Beer, and More Beer!

From compressors to nitrogen generators to blowers, we've got the ideal suite of products that help your brewery brew the perfect pint at the lowest cost of ownership.
Beer Pouring Hero Image Breweries

Service in the USA

Explore our wide variety of service options, ranging from service plans and parts plans to piping and installation, system design, and air audits and air analysis.
Service Tech Image 1

Visit The Compressed Air Blog!

Are you looking to learn more about the compressed air industry? Do you have pressing questions about compressed air and gas systems? Look no further!
compressed-air-blog
Close

Industrial water chiller TCA

Meet the TCA process cooling chiller, our newest innovation in the chiller range for optimized energy savings

Atlas Copco TCA55-215 series is a hybrid Plug'n'Play water chiller featuring a free-cooling section and patented adiabatic pre-cooling on the inlet. 

Industrial water chiller TCA

Key technical specifications

Top Downloads

Brochure
Industrial water chiller TCA
Download
Download
View all Downloads
    Contact us

Description

Energy efficient TCA chiller

This graph shows the difference between the energy consumption of a free-cooling chiller versus a non-free-cooling variant. When the TCA is operating in free-cooling mode, only the speed-regulated fans are consuming energy.

The compressors, the main energy consumers for a chiller are either off or working in a partial load mode. The graph’s blue zone shows the direct benefit form using the free-cooling principle.

Energy consumption of chillers

A = Kw/h, B = Degrees C, 1 = Chiller, 2 = Free-cooling, 3 = Free-cooling savings zone

A = Electricity
B = Purchase cost
C = 39% Free cooling savings

Energy savings chillers


Our engineering team has many years of experience in designing and calculating complex energy saving equipment.

Based on estimations and prepared for different climatic zones, we can state with confidence that the benefits of using an integrated free-cooling TCA55-215 chiller can bring you up to 40% savings of total power consumption for a 5-year life-cycle cost.


High ambient temperatures affect the performance of the chiller. In this case, the use of adiabatic panels to decrease the temperature of the air inlet on coils is a perfect solution. It enables to gain a boost of 10-15% in dry ambient conditions.

The adiabatic system is placed on the two sides of the unit to help the unit’s condensation, only during warm periods of the year, by spraying cold water on adiabatic panels placed on the fan’s air suction to reduce the air temperature.

The adiabatic system is run by a patented control philosophy with the aim to reduce water and energy consumption as much as possible without any temperature set-point deviation.

Adiabatic panels for chillers

Benefits

Technical benefits

Variety of industrial applications
The components of the chiller allow it to be used with a wide range of applications across industrial sectors. 
Chillers for indoor and outdoor installation
TCA55-215 chiller series can be installed both indoors and outdoors, thanks to the use of reliable IP54-protected components.
Meets seasonal energy performance ratio
TCA55-215’s full range complies with the EcoDesign Directive 2021 meet the Seasonal Energy Performance Ratio (SEPR1) to reach the highest level of energy saving.
TCA hybrid chiller

Downloads

Brochure TCA industrial water chiller
  • Title

    File

Related products

Related products

Services

Additional services