Keep your costs low
Keep your costs low with NGM⁺ and its lowest total cost of ownership in its class. It requires 20% less feed air than a traditional generator and it does not need a wasteful feed air heater.
Reliable operations
NGM⁺ guarantees a continuous supply of dry, high-quality nitrogen with a stable purity to keep your operations running. A soft start protects membrane and extends lifetime.
Compact & silent
Quit operation allows you to install the machine on your production floor. No external tanks are needed for operations with stable flow.
Reliable on-site nitrogen generation with best-in-class performance
Membrane technology has traditionally offered high-quality, reliable on-site nitrogen generation. Atlas Copco’s new NGM⁺ 7-70 now raises the bar with an important additional benefit: low energy costs. The high-efficiency generator comes with the lowest cost of ownership available on the market today.
Technical specifications
Type
|
|
Nitrogen – FND |
Dimensions (W x D x H) |
Weight |
|||||||
95% |
96% |
97% |
98% |
99% |
99.5% |
mm |
in |
kg |
lbs |
||
NGM 7+ |
FND Nm³/h |
25 |
21 |
17.2 |
13.4 |
9.6 |
7.1 |
820 x 772 x 2090 |
32 x 30 x 82 |
228 |
503 |
FND Scfm |
14.5 |
12.3 |
10.1 |
7.9 |
5.7 |
4.2 |
820 x 772 x 2090 |
32 x 30 x 82 |
228 |
503 |
|
NGM 14+ |
FND Nm³/h |
49 |
42 |
34 |
27 |
19.3 |
14.2 |
820 x 772 x 2090 |
32 x 30 x 82 |
251 |
553 |
FND Scfm |
29 |
25 |
20 |
15.8 |
11.3 |
8.4 |
820 x 772 x 2090 |
32 x 30 x 82 |
251 |
553 |
|
NGM 21+ |
FND Nm³/h |
74 |
63 |
52 |
40 |
29 |
21 |
820 x 1470 x 2090 |
32 x 58 x 82 |
472 |
1041 |
FND Scfm |
44 |
37 |
30 |
24 |
17 |
12.6 |
820 x 1470 x 2090 |
32 x 58 x 82 |
472 |
1041 |
|
NGM 28+ |
FND Nm³/h |
99 |
84 |
69 |
54 |
39 |
28 |
820 x 1470 x 2090 |
32 x 58 x 82 |
499 |
1100 |
FND Scfm |
58 |
49 |
41 |
32 |
23 |
16.8 |
820 x 1470 x 2090 |
32 x 58 x 82 |
499 |
1100 |
|
NGM 35+ |
FND Nm³/h |
123 |
105 |
86 |
67 |
48 |
36 |
820 x 1470 x 2090 |
32 x 58 x 82 |
553 |
1219 |
FND Scfm |
73 |
62 |
51 |
39 |
28 |
21 |
820 x 1470 x 2090 |
32 x 58 x 82 |
553 |
1219 |
|
NGM 42+ |
FND Nm³/h |
148 |
125 |
103 |
81 |
58 |
43 |
820 x 1470 x 2090 |
32 x 58 x 82 |
576 |
1270 |
FND Scfm |
87 |
74 |
61 |
47 |
34 |
25 |
820 x 1470 x 2090 |
32 x 58 x 82 |
576 |
1270 |
|
NGM 49+ |
FND Nm³/h |
173 |
146 |
121 |
94 |
67 |
50 |
820 x 1470 x 2090 |
32 x 58 x 82 |
617 |
1360 |
FND Scfm |
102 |
86 |
71 |
55 |
40 |
29 |
820 x 1470 x 2090 |
32 x 58 x 82 |
617 |
1360 |
|
NGM 56+ |
FND Nm³/h |
198 |
167 |
138 |
107 |
77 |
57 |
820 x 1470 x 2090 |
32 x 58 x 82 |
642 |
1415 |
FND Scfm |
116 |
98 |
81 |
63 |
45 |
34 |
820 x 1470 x 2090 |
32 x 58 x 82 |
642 |
1415 |
|
NGM 63+ |
FND Nm³/h |
222 |
188 |
155 |
121 |
87 |
64 |
820 x 1470 x 2090 |
32 x 58 x 82 |
688 |
1517 |
FND Scfm |
131 |
111 |
91 |
71 |
51 |
38 |
820 x 1470 x 2090 |
32 x 58 x 82 |
688 |
1517 |
|
NGM 70+ |
FND Nm³/h |
247 |
209 |
172 |
134 |
96 |
71 |
820 x 1470 x 2090 |
32 x 58 x 82 |
713 |
1572 |
FND Scfm |
145 |
123 |
101 |
79 |
57 |
42 |
820 x 1470 x 2090 |
32 x 58 x 82 |
713 |
1572 |
Keep your energy costs in check: the no-heater solution
Some membrane N₂ generators use a feed air heater to boost performance. However, these heaters use a lot of energy, inflating your operational costs. The NGM⁺ doesn’t require a heater to reach maximum capacity. The result: a substantial reduction in your running costs.